R&S®VHF/UHF Multichannel Transmitters

VHF R&S SU452U(.), UHF R&S SD432U(.), VHF/UHF R&S ST452U(.)

Options

Designation
Type
Uses, specifications, features and benefits
Options
Control Unit
R&S® GB406
For ground-to-air and naval radiocommunications.
Note: For further information, see Related Links at the bottom of this page
Bus Coupler
R&S® GV400
For the configuration of complex radio systems with several (m) Control Units R&S® GB406 and several (n) radios
Note: For further information, see Related Links at the bottom of this page
Front Options
LINK 11 Module
R&S® VX411
  • For operation with wideband AF signals in LINK 11 mode for special data transmissions in defense applications(NATO)
  • For use in conjunction with IF/AF Unit R&S® VZ400D2 and Cipher/LINK 11 Interface R&S® GI412U
  • LINK 11 specification according to STANAG 5511 (2nd edition)
  • Design: 1/16 19" front module

  • Note: For standalone RX equipment R&S® VX411 is not required for LINK 11 operation (R&S® VZ400D2 and R&S® GI412U are sufficient)
UHF Circulator Set
R&S® GD430U
  • For interference-free transmission under critical collocation conditions, i.e. many transmitting antennas cosited
  • For reduction of the TX intermodulation by increasing the backward intermodulation attenuation
  • Suppression or reduction of unwanted mixture products which are generated in the transmitter in an electromagnetic environment and which interfere with the actual frequency band
  • Integration: the circulator module of this set can be
    - interfaced in front of the harmonics filter where it is most effective and
    - mounted directly onto the heat sink of the UHF or VHF/UHF power amplifier
Rear Options
Wideband/Frequency Interface
R&S® GI411U
  • Wideband AXX data communication
  • External AGC indication
  • EPM (ECCM) operation
Cipher/LINK 11 Interface
R&S® GI412U
  • Cipher operation with standalone KY-58 cipher unit (operated without HAVE QUICK EPM (ECCM) processor in fixed-channel mode)
  • Cipher operation with other COMSEC devices (TDB)
  • With control facility of plain or cipher text, baseband (NB) or diphase (WB)
  • LINK 11 modem connection
AF/V24 Interface
R&S® GI413U
  • AF line connection (not required for AF in connection with DTMF)
  • PTT via separate or AF phantom line
  • V24/RS-232-C/RS-485 bus control
  • Cipher operation
  • EPM (ECCM) operation
  • AF level control: ALC (automatic level control) amplifier included
  • Separate GUARD RX AF outputs
  • Relay outputs for TEST, CARRIER and/or MAIN RX SQUELCH and
  • SQUELCH of GUARD RX 1 + 2 (recommended for special transceiver type models for two R&S® ET402)
Filter/PA Interface
R&S® GI414U
  • Control of 1 (2) automatically tuned filter(s)
  • Control of 1 (2) Rohde&Schwarz linear power amplifier(s)

  • Note: Model .04 is for 2 filters and amplifiers each
DTMF Interface
R&S® GI416U
  • DTMF (dual tone multiple frequency) code radio control (incl. AF) according to ITU-T recommendation Q 23 for Control Units R&S® GB406C3/H3/S3
  • V.11 (X.27)/RS-422-A (R&S® Series400 F-type) radio control: for Control Units R&S® GB404 or R&S® GB408
  • PTT by 2040 Hz tone via AF line (with tone-operated switch and filters) MAIN/STANDBY switching
  • Customer-specific I/O ports, controlled from a PC or by DTMF, allowing the display of user-definable tests (BIT) via Control Units R&S® GB406C/H/S…
AF/Telephone Interface
R&S® GI419U
  • AF line connection
  • TX and RX AF/telephone line protection
  • With 1.5 kV isolated 600 O transformers to protect the radio/operator according to EN4103/BZT guideline
  • With lightning fine protection
  • PTT via phantom circuit
  • Transmitting with 8.33 kHz channel spacing
  • With TX AF filter with 4 switchable upper stop frequencies 2.5/2.7/2.9/3.15 kHz (3.4 kHz in addition as radio standard)
  • Local and remote filter selection
DC/100 W FM Interface R&S® GI420U
  • Models .02 and .03: DC supply of Control Units R&S® GB406C/H/S…
  • Model .03: connection of Power Supply R&S® IZ450 for 100 W FM UHF operation
Parallel Interface R&S® GI421U Parallel control via previous R&S® Series400 N-type interface
  • from Control Unit R&S® GB403
  • from other N-type equipment
LINK 11 Interface R&S® GI422U
  • LINK 11 modem connection if COMSEC is not required
  • LINK 11 squelch signaling

  • Note: R&S® VX411 is not required for this application
Auxiliary Equipment
Power Supply
R&S® IZ450
For upgrade of a transmitter or transceiver to 100 W FM UHF
  • Generation of the collector voltage for this mode
  • Sensor-controlled forced air cooling of the radio (the sensors measure the heat sink temperature of R&S® VD430U or R&S® VT450U power amplifier)

19" 3 HU add-on unit for installation underneath the radio unit: the cooling air is sucked in from the front and routed upwards to the cooling fins of the amplifier heat sink; AC and DC with automatic switchover (priority to AC)
EPM (ECCM) Add-Ons
R&S® GP...
Upgrade of fixed-channel radios to EPM (ECCM)
Separate units for cabled connection to the basic radio unit (transceiver, transmitter or receiver);
different versions are available:
EPM (ECCM) Processor
R&S® GP407H1
For HAVE QUICK; DC operated from radio; 19" 1 HU
EPM (ECCM) Processor
R&S® GP407S1
For R&S® SECOS (secure EPM (ECCM) communication system) and for voice only; AC + DC; 19" 1 HU
Data Preprocessor
R&S® GP603P3
For R&S® SECOS (secure EPM (ECCM) communication system) and for data; DC; W × H × D = 50 mm × 130 mm × 295 mm
Service Kits
R&S® KA400
The kits include a wide variety of special-to-type test devices for workshop maintenance/service, such as extender and test cables, extender cards, test adapters. They all are packed in a handy portable case with individually shaped foam inserts and user information.
Available types:

R&S® KA403U
For all R&S® Series400U transmitters, receivers and transceivers

R&S® KA406
For Control Units R&S® GB406C/H/S…

R&S® KA407
For EPM (ECCM) Processors R&S® GP407H1/S1 and timing systems of R&S® GT400 family
Accessories
Audio Accessories Indispensable for local operation or test of transmitters and transceivers; flexible coil-type cable and mounted NF7 connector; also suitable for Remote Control Units R&S® GB406C/H/S… (standard models)
Handset
R&S® GA013
Handle-integrated PTT button; rugged type
Headset
R&S® GA015
Earphones-microphone combination, with cable-integrated PTT button; standard type
Headset
R&S® GA015L
Earphones-microphone combination, with cable-integrated PTT button; light version
Headset
R&S® GA012
Earphones-microphone combination, with cable-integrated PTT button; rugged type
Microphone
R&S® GA016H1
Dynamic; handheld type with PTT button
Set of Mating Connectors
R&S® XT452UZ
For all R&S® Series 400U radios (transceivers, transmitters and receivers)
xx = 12: standard set, incl. connectors for R&S® GI413/416/430U
xx = 13: extended set with additional connectors for all slots
The sets include RF connectors and are without AC connectors (as AC power cord issupplied with radio equipment)